Every published operating temperature range in the UniFi catalogue — and an honest answer to “will it survive a Calgary winter.”
Specs verified 16–17 July 2026 against techspecs.ui.com. Every figure on this page is Ubiquiti’s own published number. Where Ubiquiti publishes nothing, this page says “Not published” rather than estimating. Contact AVNFi to have a design checked.

Gate Hub — rated to −30 °C

G6 Turret — rated to −30 °C
← Door Access is the simple version of the headline finding here. This page is the whole range, with the verbatim ratings.
Why this page exists
Almost nobody documents this, and in Calgary it decides jobs.
Ubiquiti publishes an operating temperature range for every camera and every Access device. It is on the spec page. It is not on the product page, it is not in the marketing, and it is not in the box. Most installers never read it, because in most of the markets these products are sold into it never matters.
Here it matters twice a year, hard.
The finding that surprises everyone: the UA-Hub-Door is rated 0 to 40 °C. It does not go below freezing. Ubiquiti’s flagship door controller has no sub-zero rating at all. Neither does the UA-Hub-Door-Mini, the EAH-8, or the Intercom Viewer.
Meanwhile the UA-Hub-Gate — the one for outdoor gates — is rated −30 to 60 °C. Ubiquiti knows exactly what it is doing. The door hub is an indoor product and the gate hub is an outdoor one, and the only place they say so is a spec row nobody reads.
This is not a defect and it is not a warning about danger. It is a design constraint, published by the manufacturer, that determines where the box goes. Put the door hub inside the heated envelope and it is an excellent product.
How to read the ratings
1. Where a device publishes two ranges, the narrower one wins. Several Access devices publish a device rating and a separate, warmer display rating. The display is part of the product. A reader rated −30 °C with a display rated −10 °C is a −10 °C product for any purpose that involves looking at the display.
2. “Effective minimum” in these tables is the most limiting published component. It is not our estimate. It is the highest of the minimums Ubiquiti published for that device.
3. −30 °C is the Calgary bar. Calgary reaches −30 °C in most winters, and colder in some. A device rated to −20 °C is not broken at −25 °C — it is outside its published operating range, which means the manufacturer makes no claim about it and neither will we.
4. A rating is not a promise about wind chill, and none of these are ratings for direct heat load. The upper bound matters on a south wall behind glass more often than people expect.
The headline findings
| Device | Rating | What that means |
|---|---|---|
| UA-Hub-Door | 0 to 40 °C | Indoor, heated only. No sub-zero rating whatsoever. |
| UA-Hub-Door-Mini | 0 to 40 °C | Same. Indoor, heated only. |
| EAH-8 (Enterprise Access Hub) | 0 to 40 °C | Same — an eight-door controller with no sub-zero rating. |
| UA-Intercom-Viewer | 0 to 40 °C | Same. It is an indoor device. |
| UA-Hub-Gate | −30 to 60 °C | Built for outside. A 90-degree span, and the outdoor answer. |
| UA-G3-Pro | Device −30 to 45 °C; display −10 to 45 °C | The display is the limit: −10 °C. The reader survives; you can’t read it. |
| UA-Intercom | Device −30 to 60 °C; display −25 to 60 °C | Display-limited to −25 °C. |
| UVC-G6-Pro-Entry | Device −30 to 50 °C; display −25 to 50 °C | Display-limited to −25 °C. |
| UVC-G6-Turret | −30 to 50 °C | Fully specified through a Calgary winter. |
| UVC-AI-PTZ | −40 to 50 °C | The coldest-rated camera Ubiquiti publishes. |
| U5G-Max-Outdoor | −40 to 65 °C | The widest range in the catalogue. Its indoor sibling U5G-Max stops at 0 °C. |
| UCG-Industrial | −30 to 50 °C | The only gateway rated for cold — fanless and ruggedized. |
| UDR-5G-Max | 0 to 40 °C | The only other gateway with a rating, and it does not go below freezing. |
| UACC-Lock-Strike-Secure-15mm | −10 to 60 °C | The fail-secure strike is rated −10 °C — warmer than the gate hub that drives it. |
| G4 Doorbell Pro | −10 to 40 °C | A doorbell rated to −10 °C, in a city that reaches −30 °C. The Doorbell Lite is −30 °C — on a Calgary front door, that is the answer. |
Read the UA-G3-Pro row twice. Ubiquiti did not hide this — they published two ranges, plainly. But a reader whose display stops at −10 °C is, on a Calgary exterior door, a keypad you cannot see for four months of the year. The device is fine. The product is not, for that placement.
Will it survive a Calgary winter?
The bar: −30 °C. Three buckets, sorted by the effective published minimum.
Rated to −30 °C or colder — specified through a Calgary winter
These carry a published rating at or below −30 °C. That is the only group we will hang outdoors, unheated, without a caveat.
| Effective minimum | SKU | Name | Operating temp (verbatim) |
|---|---|---|---|
| -40°C | U5G-Max-Outdoor | UniFi 5G Max Outdoor | -40 to 65° C (-40 to 149° F) |
| -40°C | UDB-Pro | Device Bridge Pro | -40 to 60° C (-40 to 140° F) |
| -40°C | UVC-AI-PTZ | AI PTZ Industrial | -40 to 50º C (-40 to 122º F) |
| -30°C | UA-G3 | G3 Reader | -30 to 45° C (-22 to 113° F) |
| -30°C | UA-G3-Fingerprint | G3 Reader Fingerprint | -30 to 50° C (-22 to 122° F) |
| -30°C | UA-G3-Flex | Reader Flex | -30 to 60° C (-22 to 140° F) |
| -30°C | UA-Hub-Gate | Gate Hub | -30 to 60° C (-22 to 140° F) |
| -30°C | UA-Ultra | Access Ultra | -30 to 40° C (-22 to 104° F) |
| -30°C | UCG-Industrial | Cloud Gateway Industrial | -30 to 50° C (-22 to 122° F) |
| -30°C | UDB-Switch | Device Bridge Switch | -30 to 40° C (-22 to 104° F) |
| -30°C | UP-Siren-PoE | Siren PoE | -30 to 50° C (-22 to 122° F) |
| -30°C | UVC-AI-Dome | AI Dome | -30 to 50° C (-22 to 122° F) |
| -30°C | UVC-AI-Turret | AI Turret | -30 to 50º C (-22 to 122º F) |
| -30°C | UVC-Doorbell-Lite | Doorbell Lite | -30 to 50° C (-22 to 122° F) |
| -30°C | UVC-G5-Turret-Ultra | G5 Turret Ultra | -30 to 50° C (-22 to 122° F) |
| -30°C | UVC-G6-Edge-Turret | G6 Edge Turret | -30 to 50º C (-22 to 122º F) |
| -30°C | UVC-G6-Entry | G6 Entry | -30 to 50° C (-22 to 122° F) |
| -30°C | UVC-G6-PTZ | G6 PTZ | -30 to 50° C (-22 to 122° F) |
| -30°C | UVC-G6-Pro-360 | G6 Pro 360 | -30 to 50º C (-22 to 122º F) |
| -30°C | UVC-G6-Pro-Turret | G6 Pro Turret | -30 to 50º C (-22 to 122º F) |
| -30°C | UVC-G6-Turret | G6 Turret | -30 to 50º C (-22 to 122º F) |
Rated colder than 0 °C but warmer than −30 °C — outdoors is outside the published rating
Every one of these is rated below freezing but not to −30 °C. Calgary reaches −30 °C most winters. Mounting these outdoors means operating outside the manufacturer’s published range on the coldest days of the year — which is a decision, not an accident. Sheltered, heated or garage-side placement keeps them inside spec.
| Effective minimum | SKU | Name | Operating temp (verbatim) |
|---|---|---|---|
| -25°C | UA-Intercom | Intercom | Device: -30 to 60° C (-22 to 140° F); Display: -25 to 60° C (-13 to 140° F) |
| -25°C | UVC-G6-Pro-Entry | G6 Pro Entry | Device: -30 to 50° C (-22 to 122° F); Display: -25 to 50° C (-13 to 122° F) |
| -20°C | UA-Reader Lite | Reader Lite | -20 to 40° C (-4 to 104° F) |
| -20°C | UVC-AI-360 | AI 360 | -20 to 40° C (-4 to 104° F) |
| -20°C | UVC-AI-LPR | AI LPR | -20 to 50° C (-4 to 122° F) |
| -20°C | UVC-AI-MS-2 | AI Multi Sensor 2 | -20 to 50º C (-4 to 122º F) |
| -20°C | UVC-AI-MS-4 | AI Multi Sensor 4 | -20 to 50º C (-4 to 122º F) |
| -20°C | UVC-AI-Pro | AI Pro | -20 to 40° C (-4 to 104° F) |
| -20°C | UVC-G5-Dome | G5 Dome | -20 to 40° C (-4 to 104° F) |
| -20°C | UVC-G5-Dome-Ultra | G5 Dome Ultra | -20 to 40° C (-4 to 104° F) |
| -20°C | UVC-G5-Flex | G5 Flex | -20 to 40° C (-4 to 104° F) |
| -20°C | UVC-G6-180 | G6 180 | -20 to 50º C (-4 to 122º F) |
| -20°C | UVC-G6-Bullet | G6 Bullet | -20 to 50° C (-4 to 122° F) |
| -20°C | UVC-G6-Dome | G6 Dome | -20 to 50º C (-4 to 122º F) |
| -20°C | UVC-G6-Edge-Bullet | G6 Edge Bullet | -20 to 50º C (-4 to 122º F) |
| -20°C | UVC-G6-Edge-Dome | G6 Edge Dome | -20 to 50º C (-4 to 122º F) |
| -20°C | UVC-G6-INS | G6 Instant | -20 to 40° C (-4 to 104° F) |
| -20°C | UVC-G6-Mini-Dome | G6 Mini Dome | -20 to 40° C (-4 to 104° F) |
| -20°C | UVC-G6-Pro-Bullet | G6 Pro Bullet | -20 to 50º C (-4 to 122º F) |
| -20°C | UVC-G6-Pro-Dome | G6 Pro Dome | -20 to 50º C (-4 to 122º F) |
| -10°C | U-AirWire | AirWire | -10 to 40° C (14 to 104° F) |
| -10°C | UA-G3-Pro | G3 Reader Pro | Device: -30 to 45° C (-22 to 113° F); Display: -10 to 45° C (14 to 113° F) |
| -10°C | UA-Retrofit-Hub-2 | Retrofit Hub | -10 to 40° C (14 to 104° F) |
| -10°C | UACC-Lock-Strike-Secure-15mm | Fail-Secure Strike Lock | -10 to 60° C (14 to 140° F) |
| -10°C | UDB-IoT | Device Bridge IoT | -10 to 50° C (14 to 122° F) |
| -10°C | UTR | UniFi Travel Router | -10 to 40° C (14 to 104° F) |
| -10°C | UVC-G4 Doorbell Pro | G4 Doorbell Pro | -10 to 40° C (14 to 104° F) |
Minimum of 0 °C or warmer — indoor, heated spaces only
These do not go below freezing at all. There is no outdoor placement in Calgary where these stay in spec. This is the group that surprises people.
| Effective minimum | SKU | Name | Operating temp (verbatim) |
|---|---|---|---|
| 0°C | EAH-8 | Enterprise Access Hub | 0 to 40° C (32 to 104° F) |
| 0°C | U5G | UniFi 5G Backup | 0 to 40° C (32 to 104° F) |
| 0°C | U5G-Max | UniFi 5G Max | 0 to 40° C (32 to 104° F) |
| 0°C | UA-Hub-Door | Door Hub | 0 to 40° C (32 to 104° F) |
| 0°C | UA-Hub-Door-Mini | Door Hub Mini | 0 to 40° C (32 to 104° F) |
| 0°C | UA-Intercom-Viewer | Intercom Viewer | 0 to 40° C (32 to 104° F) |
| 0°C | UACC-Chime-PoE | PoE Smart Chime | 0 to 40° C (32 to 104° F) |
| 0°C | UDR-5G-Max | Dream Router 5G Max | 0 to 40° C (32 to 104° F) |
| 0°C | UP-Chime | WiFi Smart Chime | 0 to 40° C (32 to 104° F) |
| 0°C | UP-Sense | All-In-One Sensor | 0 to 45° C (32 to 113° F) |
| 0°C | USL-Entry | Entry Sensor | 0 to 40° C (32 to 104° F) |
| 0°C | USL-Motion | Motion Sensor | 0 to 40° C (32 to 104° F) |
Every published temperature range, in one table
Sorted coldest-rated first. Verbatim from techspecs.ui.com.
| Category | SKU | Operating temp (verbatim) | Effective minimum |
|---|---|---|---|
| Camera | UVC-G4 Doorbell Pro | -10 to 40° C (14 to 104° F) | -10°C |
| Access | UA-G3-Pro | Device: -30 to 45° C (-22 to 113° F); Display: -10 to 45° C (14 to 113° F) | -10°C |
| Access | UACC-Lock-Strike-Secure-15mm | -10 to 60° C (14 to 140° F) | -10°C |
| Access | UA-Retrofit-Hub-2 | -10 to 40° C (14 to 104° F) | -10°C |
| Bridging / connectivity | UDB-IoT | -10 to 50° C (14 to 122° F) | -10°C |
| Bridging / connectivity | U-AirWire | -10 to 40° C (14 to 104° F) | -10°C |
| Bridging / connectivity | UTR | -10 to 40° C (14 to 104° F) | -10°C |
| Camera | UVC-G6-Dome | -20 to 50º C (-4 to 122º F) | -20°C |
| Camera | UVC-G6-Mini-Dome | -20 to 40° C (-4 to 104° F) | -20°C |
| Camera | UVC-G6-Pro-Dome | -20 to 50º C (-4 to 122º F) | -20°C |
| Camera | UVC-G6-Edge-Dome | -20 to 50º C (-4 to 122º F) | -20°C |
| Camera | UVC-G6-180 | -20 to 50º C (-4 to 122º F) | -20°C |
| Camera | UVC-G6-Bullet | -20 to 50° C (-4 to 122° F) | -20°C |
| Camera | UVC-G6-Pro-Bullet | -20 to 50º C (-4 to 122º F) | -20°C |
| Camera | UVC-G6-Edge-Bullet | -20 to 50º C (-4 to 122º F) | -20°C |
| Camera | UVC-G6-INS | -20 to 40° C (-4 to 104° F) | -20°C |
| Camera | UVC-G5-Dome | -20 to 40° C (-4 to 104° F) | -20°C |
| Camera | UVC-G5-Dome-Ultra | -20 to 40° C (-4 to 104° F) | -20°C |
| Camera | UVC-G5-Flex | -20 to 40° C (-4 to 104° F) | -20°C |
| Camera | UVC-AI-360 | -20 to 40° C (-4 to 104° F) | -20°C |
| Camera | UVC-AI-MS-2 | -20 to 50º C (-4 to 122º F) | -20°C |
| Camera | UVC-AI-MS-4 | -20 to 50º C (-4 to 122º F) | -20°C |
| Camera | UVC-AI-LPR | -20 to 50° C (-4 to 122° F) | -20°C |
| Camera | UVC-AI-Pro | -20 to 40° C (-4 to 104° F) | -20°C |
| Access | UA-Reader Lite | -20 to 40° C (-4 to 104° F) | -20°C |
| Camera | UVC-G6-Pro-Entry | Device: -30 to 50° C (-22 to 122° F); Display: -25 to 50° C (-13 to 122° F) | -25°C |
| Access | UA-Intercom | Device: -30 to 60° C (-22 to 140° F); Display: -25 to 60° C (-13 to 140° F) | -25°C |
| Camera | UVC-G6-Turret | -30 to 50º C (-22 to 122º F) | -30°C |
| Camera | UVC-G6-Pro-Turret | -30 to 50º C (-22 to 122º F) | -30°C |
| Camera | UVC-G6-Edge-Turret | -30 to 50º C (-22 to 122º F) | -30°C |
| Camera | UVC-G6-Pro-360 | -30 to 50º C (-22 to 122º F) | -30°C |
| Camera | UVC-G6-PTZ | -30 to 50° C (-22 to 122° F) | -30°C |
| Camera | UVC-G5-Turret-Ultra | -30 to 50° C (-22 to 122° F) | -30°C |
| Camera | UVC-AI-Turret | -30 to 50º C (-22 to 122º F) | -30°C |
| Camera | UVC-AI-Dome | -30 to 50° C (-22 to 122° F) | -30°C |
| Camera | UVC-Doorbell-Lite | -30 to 50° C (-22 to 122° F) | -30°C |
| Camera | UVC-G6-Entry | -30 to 50° C (-22 to 122° F) | -30°C |
| Access | UA-Hub-Gate | -30 to 60° C (-22 to 140° F) | -30°C |
| Access | UA-G3 | -30 to 45° C (-22 to 113° F) | -30°C |
| Access | UA-G3-Flex | -30 to 60° C (-22 to 140° F) | -30°C |
| Access | UA-G3-Fingerprint | -30 to 50° C (-22 to 122° F) | -30°C |
| Access | UA-Ultra | -30 to 40° C (-22 to 104° F) | -30°C |
| Sensor / accessory | UP-Siren-PoE | -30 to 50° C (-22 to 122° F) | -30°C |
| Gateway | UCG-Industrial | -30 to 50° C (-22 to 122° F) | -30°C |
| Bridging / connectivity | UDB-Switch | -30 to 40° C (-22 to 104° F) | -30°C |
| Camera | UVC-AI-PTZ | -40 to 50º C (-40 to 122º F) | -40°C |
| Bridging / connectivity | UDB-Pro | -40 to 60° C (-40 to 140° F) | -40°C |
| Bridging / connectivity | U5G-Max-Outdoor | -40 to 65° C (-40 to 149° F) | -40°C |
| Access | UA-Hub-Door | 0 to 40° C (32 to 104° F) | 0°C |
| Access | UA-Hub-Door-Mini | 0 to 40° C (32 to 104° F) | 0°C |
| Access | UA-Intercom-Viewer | 0 to 40° C (32 to 104° F) | 0°C |
| Access | EAH-8 | 0 to 40° C (32 to 104° F) | 0°C |
| Sensor / accessory | UACC-Chime-PoE | 0 to 40° C (32 to 104° F) | 0°C |
| Sensor / accessory | UP-Chime | 0 to 40° C (32 to 104° F) | 0°C |
| Sensor / accessory | UP-Sense | 0 to 45° C (32 to 113° F) | 0°C |
| Sensor / accessory | USL-Entry | 0 to 40° C (32 to 104° F) | 0°C |
| Sensor / accessory | USL-Motion | 0 to 40° C (32 to 104° F) | 0°C |
| Gateway | UDR-5G-Max | 0 to 40° C (32 to 104° F) | 0°C |
| Bridging / connectivity | U5G | 0 to 40° C (32 to 104° F) | 0°C |
| Bridging / connectivity | U5G-Max | 0 to 40° C (32 to 104° F) | 0°C |
| Access | UACC-PanicBar | Not published | Not published |
Where the ratings simply don’t exist
Coverage is not uniform, and the holes are in a revealing pattern.
| Section | Rows publishing an operating temperature |
|---|---|
| Cameras | 30 of 30 |
| UniFi Access | 14 of 15 |
| Sensors and accessories | 6 of 6 |
| Bridging and connectivity | 8 of 8 |
| Gateways | 2 of 15 |
| Switches | 0 of 20 — none |
| Access points | 0 of 28 — none |
Not one switch and not one access point publishes an operating temperature. Forty-eight products, zero ratings. Only 2 of 15 gateways publish one — the UCG-Industrial (−30 to 50 °C, fanless, ruggedized) and the UDR-5G-Max (0 to 40 °C).
That is a real hole and we are not going to fill it with a plausible-sounding number.
What we can say honestly:
- For switches and most gateways it matters less than it sounds, because they live indoors in a rack or a cupboard by definition. If your switch is seeing −30 °C you have a bigger problem than the spec sheet. Notably, the one gateway Ubiquiti built for rough environments is the one it bothered to rate — the UCG-Industrial is fanless and rated to −30 °C, and that is not a coincidence.
- It matters much more for access points, because U7 Outdoor, U7 Pro Outdoor, E7 Campus and E7 Audience are sold as outdoor products — and Ubiquiti publishes no temperature rating for any of them. If an outdoor AP’s cold rating is a requirement for your job, that is a question for Ubiquiti and the answer needs to be in writing. We will not guess it for you.
- Unheated garages, sheds, attics and outbuildings are the real risk, because that is where people put switches without thinking about it. A shed at −25 °C is outside every published rating we hold — because for a switch there is no published rating to be outside of.
The one place Ubiquiti does rate its outdoor gear properly
The bridging and connectivity range publishes a temperature for all 8 of its products, and the outdoor ones are rated seriously:
- U5G-Max-Outdoor — −40 to 65 °C, IPX6 (IP67 with the cable-gland door kit). The widest range in the entire catalogue.
- UDB-Pro — −40 to 60 °C, IPX6, wind loading published at 69 N at 200 km/h.
- UDB-Switch — −30 to 40 °C.
And the indoor ones are rated honestly as indoor: U5G at 0 to 40 °C, U5G-Max at 0 to 40 °C, UTR at −10 to 40 °C, U-AirWire at −10 to 40 °C, UDB-IoT at −10 to 50 °C.
Same pattern as the door hub and the gate hub. Ubiquiti builds an indoor variant and an outdoor variant, rates them accurately, and puts the distinction in the one row nobody reads. U5G-Max and U5G-Max-Outdoor are not “the same modem, weatherproofed” — one stops at 0 °C and the other goes to −40 °C.
The practical consequences
1. The door hub goes inside. Always. UA-Hub-Door at 0 °C means the controller lives in the heated envelope and only the reader goes outside. That is how the product is designed — the reader is rated −30 °C precisely so the hub doesn’t have to be.
2. Gate jobs use the gate hub, not the door hub. UA-Hub-Gate is −30 to 60 °C for exactly this reason. Substituting a door hub into an outdoor gate enclosure to save money puts a 0 °C-rated device in a −30 °C location.
3. Check the display rating before you specify a display. UA-G3-Pro (−10 °C), UA-Intercom (−25 °C), UVC-G6-Pro-Entry (−25 °C). All three have device ratings of −30 °C and displays that stop sooner.
4. The strike is rated −10 °C. The UACC-Lock-Strike-Secure-15mm is −10 to 60 °C, which is warmer than the −30 °C gate hub that can drive it. On a genuinely exterior door the strike is the limiting component, not the electronics.
5. On cameras, the split is close to a clean line — but not quite. Rated −30 °C or colder: all three G6 turrets (Turret, Pro Turret, Edge Turret), G6 PTZ, G6 Pro 360, G5 Turret Ultra, Doorbell Lite, G6 Entry, AI Turret, AI Dome, and the AI PTZ Industrial at −40 °C. Rated −20 °C: every bullet, every dome except the AI Dome, both multi-sensors, the AI LPR and the AI Pro. If the camera is going on an exposed north wall, the first list is the list — and note that the AI Dome is the one dome that makes it.
6. Nothing here is safety advice. These are operating ranges published by a manufacturer. How a door behaves in a fire, what your code requires, and what your insurer wants are all questions for people qualified to answer them. We install to the spec and we tell you what the spec says.
Related
- Door Access — the simple version: hubs, readers, and the egress point
- Cameras: the full spec matrix — every camera’s temperature range in context
- PoE reference — the other half of the power story
- Garage / Gate Integration — a worked design with the cold constraint in it
- Warehouse / Shop — height, distance and cold
- Glossary — every term above, defined once
All temperature ranges from techspecs.ui.com, captured 2026-07-16, reproduced verbatim. Where Ubiquiti publishes no rating, this page says so. AVNFi, Calgary.